[Beckman Coulter] - CytoFLEX 유세포 분석 구성

드림셀인스 2024-04-08 조회수 112

The CytoFLEX nano Flow Cytometer is the first nanoscale flow cytometer



Launch of the CytoFLEX nano Flow Cytometer



✨ Get ready to break the boundaries of EV detection!

Explore the full picture of your EV experiment with the CytoFLEX nano flow cytometer.

With the ability to count, size, and characterize EVs using a single technique, it propels your research forward.

Experience greater sensitivity, consistent instrument performance, and flexibility to study your sample.

With the CytoFLEX nano flow cytometer, we have lowered the limits of detection, so you can achieve more.

Research use only. Not for use in diagnostic procedures.







Meet the CytoFLEX nano Flow Cytometer. A pivotal development in flow cytometry, the CytoFLEX nano analyzer enables the analysis of EVs at least as small as 40 nm* with ease while simultaneously offering up to 6 separate fluorescent channels of detection, to deliver full characterization.


With the CytoFLEX nano Flow Cytometer, you can expect:


   - Increased size sensitivity from 1 μm to at least 40 nm*

   - Flexibility for your experimental design with 6 fluorescent channels and 5 side scatter channels

   - Consistency of results with >90% volumetric counting accuracy and <1% carryover between samples


*Characterized using 40 nm polystyrene beads and triggering on violet side scatter.








PERFORMANCE


CytoFLEX nano Flow Cytometer Performance
 Violet side scatter sensitivityVSSC1: 40 nm relative to polystyrene nanoparticles
VSSC2: 80 nm relative to polystyrene nanoparticles
Scatter detection dynamic rangeVSSC 1 for small range 40-150 nm polystyrene nanoparticles
VSSC2 for large range 80-1000 nm polystyrene nanoparticles
Violet forward scatter sensitivity300 nm relative to polystyrene nanoparticles
Fluorescence sensitivity and resolution

 Simultaneous detection of fluorescence on six fluorescence detectors, using 500 nm CytoFLEX nano Multi-intensity Fluorospheres

V477: 8 peaks

B531: 8 peaks

Y595: 8 peaks

R670: 6 peaks

R710: 5 peaks

R792: 4 peaks

 Fluorescence rCVCV < 10% (using QC Fluorospheres at 1 µL/min)
Carryover between Samples≤1%a
 Acquisition speedMaximum electronic acquisition speed16000 events/second with ≤ 95% yield
Recommended maximum sample acquisition speed5000 events/second to avoid possible swarming or coincidence situations.
 Volumetric Counting accuracy> 90%b
a. Tested with polystyrene nanoparticles.
b. Tested with 144 nm QC Scatterspheres on 3 units under the conditions: record 3 minutes at the sample flow rates of 1μL/min, 2μL/min, 3μL/min,
4μL/min, 5μL/min, 6μL/min respectively, repeat 5 times, then calculated the average total events for each speed, compared the calculated the
volumetric counting accuracy with the theoretical total events (the known concentration 1.3*108 x volume).